Mitsubishi FR-A8NCE

Mitsubishi FR-A8NCE
Details:
Brand: Mitsubishi
Model:FR-A8NCE
Inventory situation: Goods are available in stock.
Send Inquiry
Description
Send Inquiry

MITSUBISHI FR-A8NCE

 

Brand: Mitsubishi
Model: FR-A8NCE

Mitsubishi FR A8NCE
Mitsubishi FR-A8NCE Inverter

Inventory situation: Goods are available in stock.

 

Product features

 

The Mitsubishi FR-A8NCE is a high-performance CC-Link IE Field communication module intended for industrial automation systems. As an internal option card for the FR-A800 series inverters, this module allows for the easy integration of variable frequency drives (VFDs) into advanced manufacturing networks, enabling real-time data interchange and precise motor control.

 

The FR-A8NCE offers 1 Gbps high-speed data transfer over standard Ethernet connections (Category 5e or higher), enabling for real-time synchronization of inverters, PLCs, and HMIs. It can support up to 120 nodes per network (including 64 inverters when using 128-word data blocks), making it appropriate for large-scale applications such as automotive assembly lines or semiconductor cleanrooms. The module effectively manages instructions, status updates, and diagnostic data using 64-bit remote input/output (RX/RY) and 128-word remote registers (RWr/RWw).

 

Its modular topology support (bus, star, ring, or hybrid configurations) provides interoperability with a wide range of industrial settings, while RJ-45 connectors make installation easier and reduce cabling complexity. The FR-A8NCE module also features error detection and line monitoring functionalities to ensure reliable communication in tough settings with electromagnetic interference.

 

Specifications

 

Transmission distance

Up to 100 meters per single segment (using Cat.5e shielded cable)

Physical interfaces

2 x RJ-45 ports (PORT1/PORT2)

Dimensions

50 mm (W) × 115.5 mm (H) × 25.6 mm (D)

Operating temperature

0°C to 55°C (non-condensing)

Humidity

5% to 95% RH (non-condensing)

Protection rating

IP20 (dust protection only)

International standards

CE (LVD/EMC), RoHS, UL 508 (Industrial Control Equipment), IEC 61800-5-1

Data circulation (per node)

64-bit input (RX), 64-bit output (RY), 128-word read (RWr), 128-word write (RWw)

 

Application scenarios

 

The FR-A8NCE is an important component in factory automation, specifically conveyor systems and machine tools. By allowing real-time data interchange via CC-Link IE Field, it enables smooth coordination between inverters and master modules, lowering starting time and enhancing maintainability. For example, in automotive assembly lines, it aids in synchronizing motor speeds, maximizing production flow, and reducing downtime. Its plug-in architecture and low current consumption make it ideal for space-constrained settings, ensuring consistent performance even under adverse conditions.

 

The FR-A8NCE improves energy efficiency in HVAC systems by managing pumps and fans. It supports modern communication protocols such as CC-Link IE TSN, which enables real-time monitoring and adjustment of equipment. This feature reduces energy consumption by up to 30% while maintaining ideal interior conditions. For example, in commercial buildings, it ensures accurate airflow regulation, increasing comfort while lowering operational expenses.

 

The water treatment industry benefits from the FR-A8NCE's capacity to manage pumps and wastewater treatment equipment. Its powerful connectivity capabilities allow for remote monitoring and rapid diagnostics, ensuring uninterrupted functioning and lowering maintenance requirements. It helps to maintain regular water pressure and quality in water treatment plants, hence supporting key processes such as filtration and disinfection.

 

FAQ

Q: What is the Mitsubishi FR-A8NCE and what is it used for?

A: The Mitsubishi FR-A8NCE is a high-performance CC-Link IE Field communication option card for the FR-A800/F800 series inverters. It integrates seamlessly with industrial Ethernet networks, enabling for real-time data interchange between inverters, PLCs, and other automation devices. Factory automation, machine control, and process optimization are common applications that require rapid, reliable communication. Key use cases include linking up to 42 devices in a single network to perform synchronized operations.

Q: How does the FR-A8NCE compare to competitors like ABB or Siemens?

A: The FR-A8NCE excels in CC-Link IE Field environments, providing more seamless connectivity with Mitsubishi PLCs and drives. Competitors such as ABB's Smart Communication Card prioritize OPC UA and Modbus TCP, whilst Siemens' SINAMICS cards focus on PROFINET. The FR-A8NCE provides unparalleled compatibility and performance in Mitsubishi-centric systems. Consider hybrid solutions with optional components when working with many vendors.

Q: Where can I find the official FR-A8NCE manual?

A: The FR-A8NCE Instruction Manual is available to download from Mitsubishi Electric's official support website. It contains thorough wiring schematics, parameter lists, and safety instructions. Key portions such as LED status codes and network topology diagrams can also be accessed quickly using third-party platforms such as Manualslib.

 

 

Hot Tags: mitsubishi fr-a8nce, China mitsubishi fr-a8nce suppliers, Mitsubishi FR CS84 080 60, mitsubishi vfd, FR E740 0 4K CHT Mitsubishi E700 Series Inverter

Send Inquiry