How to set the auto - restart function of Omron VFD?

Oct 24, 2025

Leave a message

David Wang
David Wang
As a content creator and technical writer for Chentuo Technology, David focuses on creating engaging and informative content that highlights the company's innovative automation solutions. His work helps educate clients about the latest advancements in industrial automation technology.

Hey there! As a supplier of Omron VFDs, I often get asked about how to set the auto-restart function. It's a pretty handy feature that can save you a lot of time and hassle, especially in industrial settings where downtime can be costly. So, I thought I'd share some tips on how to do it.

First off, let's talk about why you might want to use the auto-restart function. In a nutshell, it allows your VFD to automatically restart after a fault or power outage. This can be really useful if you're running a continuous process that can't afford to stop. For example, if you're using a VFD to control a conveyor belt in a factory, an auto-restart function can ensure that the belt starts up again as soon as the power is restored or the fault is cleared.

Now, let's get into the nitty-gritty of how to set the auto-restart function. The process can vary depending on the specific model of your Omron VFD, but I'll go through the general steps that apply to most models.

Step 1: Access the Parameter Menu

The first thing you need to do is access the parameter menu of your VFD. This is usually done by pressing the "Mode" or "Menu" button on the VFD's control panel. Once you're in the parameter menu, you'll need to navigate to the section that deals with the auto-restart function. This section is often labeled something like "Auto Restart" or "Restart After Fault."

Step 2: Enable the Auto-Restart Function

Once you're in the auto-restart section of the parameter menu, you'll need to enable the function. This is usually done by setting a specific parameter to "On" or "Enable." The exact parameter name and value can vary, so you'll need to refer to your VFD's user manual for the exact details.

Step 3: Set the Restart Delay

After enabling the auto-restart function, you'll need to set the restart delay. This is the amount of time that the VFD will wait before attempting to restart after a fault or power outage. The restart delay can be set in seconds or minutes, depending on your VFD model. Setting a restart delay can be useful if you need to give the system time to recover from a fault or if you want to stagger the restart of multiple VFDs to avoid overloading the power supply.

Step 4: Set the Number of Restart Attempts

You'll also need to set the number of restart attempts that the VFD will make. This is the maximum number of times that the VFD will try to restart after a fault or power outage. If the VFD fails to restart after the specified number of attempts, it will usually lock out and display an error message. Setting the number of restart attempts can help prevent the VFD from continuously trying to restart in a situation where it's not going to work, which can save energy and prevent damage to the equipment.

Step 5: Set the Restart Mode

Finally, you'll need to set the restart mode. There are usually two main restart modes: "Current Frequency Restart" and "Zero Frequency Restart." In the current frequency restart mode, the VFD will try to restart at the frequency it was running at before the fault or power outage. In the zero frequency restart mode, the VFD will start from zero frequency and gradually ramp up to the set speed. The choice of restart mode depends on your specific application and the requirements of your equipment.

Omron 3G3MX2-A2007-V13G3MX2-A4030-E Omron 3

Now, let's take a look at some specific Omron VFD models and how to set the auto-restart function for them.

Omron 3G3MX2-A2007-V1

The Omron 3G3MX2-A2007-V1 is a popular VFD model that offers a range of features, including an auto-restart function. To set the auto-restart function for this model, you'll need to access the parameter menu by pressing the "Mode" button on the control panel. Then, navigate to the "Auto Restart" section and set the "Auto Restart Enable" parameter to "On." You can then set the restart delay, number of restart attempts, and restart mode as described above.

Omron 3G3MX2-A4030-E

The Omron 3G3MX2-A4030-E is another great VFD model that comes with an auto-restart function. To set the auto-restart function for this model, access the parameter menu using the "Menu" button on the control panel. Find the "Restart After Fault" section and enable the auto-restart function. Then, adjust the restart delay, number of restart attempts, and restart mode according to your needs.

Omron Frequency Inverter 3G3JZ-A4007

The Omron Frequency Inverter 3G3JZ-A4007 is a compact and reliable VFD that also supports the auto-restart function. To configure the auto-restart function on this model, enter the parameter menu by pressing the appropriate button on the control panel. Locate the relevant auto-restart parameters and set them as required.

It's important to note that these are just general guidelines, and you should always refer to the user manual for your specific Omron VFD model for detailed instructions. The user manual will provide you with the exact parameter names, values, and procedures for setting the auto-restart function.

If you're having trouble setting the auto-restart function or if you have any other questions about Omron VFDs, don't hesitate to reach out. As a supplier, I'm here to help you get the most out of your VFDs. Whether you're a small business owner looking to improve the efficiency of your operations or a large industrial company in need of reliable VFD solutions, I can provide you with the right products and support.